* Cardinal XL Edge Dual Seal Insulated Glass Units without grids.
“U” Factor:The rate of non solar heat loss or gain through a given glazing. The lower the number, the better the insulating quality.
Solar Heat Gain Coefficient: The fraction of direct solar radiation that enters a building thru the glass as heat. Lower numbers mean the glazing lets less heat in.
Visible Light Transmittance: Measures the amount of light transmitted through the glass. VT is expressed as a number between 0 and 1. The higher the VT, the more light is transmitted.
820 AAMA Certified Window Performance Ratings
|
|
|
|
Uniform Structural
Load MPH |
5 Gal/Ft/Hour=8"/Hr
Water Resistance MPH
|
Horizontal Slider |
|
|
|
|
|
|
820
Horizontal Slider |
|
|
|
45 PSF = 134 MPH
30 PSF = 109 MPH
|
4.5 PSF = 42 MPH
AIR = .17 cfm/ft∧2
4.5 PSF = 42 MPH
AIR = .17 cfm/ft∧2
|
|
|
|
|
|
|
| 820
Horizontal Slider XOX |
|
|
|
|
3.0 PSF = 35 MPH
AIR = .11 cfm/ft∧2
|
|
|
|
|
|
|
| 820
Single Hung |
|
|
|
|
4.5 PSF = 42 MPH
AIR = .15 cfm/ft∧2
|
|
|
|
|
|
|
| 820
|
|
|
|
|
12 PSF = 69 MPH
AIR =0 .00 cfm/ft∧2
|
|
|
|
|
|
|
| 820
Fixed Over XOX |
|
|
|
|
3.0 PSF = 35 MPH
AIR = .11 cfm/ft∧2
|
|
|
|
|
|
|
| 820
Double Single Hung |
|
|
|
|
3.0 PSF = 35 MPH
AIR = .15 cfm/ft∧2
|
|
|
|
|
|
|
| 820
Single Hung-Picture
Window-Single Hung |
|
|
|
|
3.0 PSF = 35 MPH
AIR = .10 cfm/ft∧2
|
|